Subcategories
Pressure and temperature sensors are available with analog or digital outputs for measurement wild ranges.
Pressure sensors or pressure transmitters, are based on the latest piezoresistive foil strain gauges and inductive measurement technology. The pressure sensors can be used for a wide variety of media and applications. In aerospace engineering the piezoresistive pressure sensors help distribute pressure across the wing’s surface. They are also used in braking systems for cars and in gas turbine tests.
Temperature Sensors are used to accurately measure temperature from a distance by detecting the infrared radiation of an object. The higher the temperature the more thermal energy is emitted by an object.
Temperature sensors can be used for a wide range of applications such as driers, ovens, metal and glass industries or semiconductor production. A variety of sensors is available such as small sized, or with the ability to withstand extreme temperatures.
Pickup Sensors, Velocity Sensors, Tacho-generators are available with a wide range of thread sizes, lead lengths and connectors. DEAmatic stock a wide range of position and velocity sensors for many different engine brands and families.
Magnetic speed sensors attach to the flywheel casing and detects when ring gear teeth pass the tip of the sensor. Electrical impulses are produced by the sensor’s internal coil and feed back to the speed control unit, so engine performance can be monitored and adjusted.
Vibration sensors are piezoelectric accelerometers that sense vibration. They are used for measuring fluctuating accelerations or speeds or for normal vibration measurement. Maintenance professionals use the sensors in order to predict the maintenance of the machinery, to reduce overall costs and increase the performance of the machinery.
The knock sensor identifies the high-frequency engine vibrations characteristic of knocking and transmits a signal to the ECU. The aim is to obtain the maximum energy yield by starting ignition as early as possible. Engines with a knock sensor can reduce fuel consumption and increase torque.
Gas sensors (also known as gas detectors) are electronic devices that detect and identify different types of gasses. They are commonly used to detect toxic or explosive gasses and measure gas concentration. Gas sensors are employed in factories and manufacturing facilities to identify gas leaks, and to detect smoke and carbon monoxide in homes. Gas sensors vary widely in size (portable and fixed), range, and sensing ability.
An oxygen sensor (or lambda sensor, where lambda refers to air–fuel equivalence ratio, usually denoted by λ) is an electronic device that measures the proportion of oxygen (O2) in the gas or liquid being analyzed.
A servomotor is a rotary actuator, linear actuator or solenoid that allows for high-response, high-precision control of angular or linear position, velocity and acceleration. As a motor capable of the accurate rotation angle and speed control, it can be used for a variety of equipment. They are used in applications such as robotics, CNC machinery or automated manufacturing and are generally used as a high-performance alternative to the stepper motor.
In automatic control, a regulator is a device which has the function of maintaining a designated characteristic. It performs the activity of managing or maintaining a range of values in a machine. The measurable property of a device is managed closely by specified conditions or an advance set value; or it can be a variable according to a predetermined arrangement scheme. It can be used generally to connote any set of various controls or devices for regulating or controlling items or objects.
A governor, or speed limiter or controller, is a device used to measure and regulate the speed of a machine, such as an engine.
Electronic governor controller is compatible with all analog governors/speed controllers from Cummins, Barber Colman, Woodward and GAC. The governor controller works with all types of hydraulically actuated governors, PT pump type (Cummins), both built-in and externally mounted
Nominal input voltage UN 24 V DC
Typical input current at UN 7 mA
Typical response time 5 ms
Typical release time 2.5 ms
Coil resistance 3390 Ω ±10 % (at 20 °C)
REL-MR- 24DC/21 – 2961105 Data sheet
Part no.: 1065616
Number of lines per revolution 1,024
Reference signal, number1
Reference signal, position 90° electric, logically gated with A and B
Measuring step deviation ± 0.01°
Connection type Cable, 8-wire, radial, 1.5 m
VFS60B-TDCK01024 Data sheet
ML441-11Y-T-2512Part no.: 1065616
Heavy duty limit switch, with Metal Roller Lever
Actuator head can be repositioned in steps 4 x 90°
Galvanized cast iron enclosure
ML441-11Y-T-M20 Data sheet
SID10ABBFPKG/US-100
• The unit detects the flow speed to the calorimetric measuring principle and
switches the output
• If the flow speed increases, the switching status changes when the switch point
is reached
• If the flow speed falls again, the switching status changes if the value "SP
minus hysteresis" is reached
SI500A manual
SDOGH040MSSFKPG
Gold-plated contacts for a secure connection
High degree of protection to meet the requirements of harsh environments
Efficient stress relief thanks to patented 3-way ball clamp technology
Simple and fast wiring with screw terminals
EVC810 data
ignites and monitors directly ignited industrial gas burners of unlimited capacity
safety time for start-up: 3, 5 or 10 s, safety time for operation: 1 s,
Mains voltage:
100 V AC, 115 V AC, 200 V AC or 230 V AC, for earthed or unearthed mains
IFD 258 manual
SDOAH040MSSFKPG
Gold-plated contacts for a secure connection
High degree of protection to meet the requirements of harsh environments
Efficient stress relief thanks to patented 3-way ball clamp technology
Simple and fast wiring with screw terminals
EVC811 data
Probe Type: Single/Dual (Configured on installation)
Phase Sense: Yes
Voltage: 230V
Flame Sensitivity: 1 - 2 uA
Purge: 12 Seconds
Ignition: 6 Seconds
Rest Switch: None
CE Approved
RoHS Compliant
CE Approved
Pactrol CSS2 manual
Robust valve control device giving a confidence in reliable performance and outstanding durability under harsh working environments
- Easy maintenance
- Precise calibration with simple SPAN and ZERO adjustments
- Simple conversion to direct acting or reverse acting
- 1/2 split range available
- Rugged aluminum housing with corrosion-resistant coating...
• IP40 rating
• Intermittent operating mode
• Average life 10,000 hours at 50 deg C
• Direct mounting on to the burner
• Comes with flange camp
QRA Datasheet
Transmitter with provision for fastening to a DIN guide
• TR-A interfaceable with accelerometers with a sensitivity of 100 mV/g (TA-18 – TA-18/S)
• TR-V interfaceable with velocimeters with a sensitivity of 21.2 mV/mm/s (T1-40 – T1-40V – T1-40BF – T1-38 – T1-38V – T1-38BF)
• TR-VMT...
The T1-40 transducer measures absolute vibration of any rotating machine support. It supplies a voltage proportional to the vibration speed directly interfaceable with a device that can process the signal (TR-V, TRAL-V, TM1, TDSP)
The T1-40 electrodynamic transducer consists of a suspended plate coil immersed in the magnetic field of a...